Search
Advanced search
Filter by category
Filter by committee
Search results
-
Although PVC gasketed sewer basins are currently being produced and supplied to the storm drainage market, there are not currently minimum requirements users can refer to for a purchase. A proposed new ASTM International standard will provide these requirements. ASTM WK32336 , Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sanitary and Storm Drainage Sewer Basins and Fittings, is being…
-
Ensuring effective knowledge of underground assets and systems is essential for gas utility companies that are implementing plans to address regulatory initiatives and reporting requirements. A new ASTM International specification provides a comprehensive plan for tracking and tracing these assets. The new standard, ASTM F2897 , Specification for Tracking and Traceability Encoding System of…
-
Innovations in the equations and other analytical tools that engineers have used when designing close-fit liners for plastic pipe have led to a need for a new standard for design calculations. This need will be met by a proposed new ASTM International standard, ASTM WK29237, Practice for Design Calculations of Close-Fit Liners. The proposed new standard is being developed by Subcommittee F17.67…
-
Two new ASTM International standards on rescue litters and fixed anchorages will contribute to the safety and efficiency of search and rescue operations. Both standards were developed by Subcommittee F32.01 on Equipment, Testing and Maintenance, part of ASTM International Committee F32 on Search and Rescue., BASKET TYPE RESCUE LITTERS, Until the development of ASTM F2821 , Test Methods for Basket Type Rescue Litters, there had not been a standardized means for manufacturers to test these rescue devices, according to John McKently, Los Angeles County Sheriff's Department, and an F32 member. “ASTM F2821 was developed because there was no standard available that allowed manufacturers to test litter products in the same way,” says…, FIXED ANCHORAGES, According to McKently, the impetus for the development of ASTM F2822 , Specification for Fixed Anchorages Installed on Structures Used for Rope Rescue Training, was similar to that of ASTM F2821. In this case, the standard was developed to provide minimum strength requirements for anchorages permanently installed or attached to training towers or other structures used for rope rescue training. “…, ASTM Committee F32 Next Meeting:, Nov. 7-10, in conjunction with the International Technical Rescue Symposium, Golden, Colo., Technical Contact:, John McKently, Los Angeles County Sheriff's Department, Glendale, Calif., Phone: 818-247-3209; jmckently@earthlink.net, ASTM Staff Contact:, Thomas O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8654
-
ASTM International Committee F17 on Plastic Piping Systems has just completed the development of two new standards for polypropylene sanitary sewer pipe. These new standards are the first to address both dual wall and triple wall profile designs. “Polypropylene has unique material characteristics, which make it ideal for sanitary sewer pipe applications,” says John Kurdziel, director, technical…
-
A newly approved ASTM International standard provides a procedure for safely conducting leakage tests of polyethylene pressure piping systems with compressed gaseous testing media. The new standard, ASTM F2786 , Practice for Field Leak Testing of Polyethylene (PE) Pressure Piping Systems Using Gaseous Media Under Pressure (Pneumatic Leak Testing), was developed by Subcommittee F17.40 on Test…
-
A proposed new ASTM International standard will allow gas utility companies to better identify underground assets, such as different types of pipe, fittings and components. From an operations perspective, effective identification is a critical component, ranging from asset management to risk management and mitigation, to help facilitate compliance with the recent Distribution Integrity Management…
-
Three primary factors define the success or failure of any attempt to forcibly penetrate a security fence system: the tools and devices employed, the number of aggressors and their level of sophistication. A newly approved ASTM International standard can be used to measure the resistance of fence systems to such an attempt. ASTM F2781 , Practice for Testing Forced Entry Resistance of Security…, ASTM Committee F14 Next Meeting:, Feb. 16, 2010 , in conjunction with American Fence Association, FENCETECH 2010, Orlando, Fla., Technical Contact:, Charles Naegele, P.E., Allied Consulting Inc., Clarks Summit, Pa., Phone: 570-586-7260; canaegele@aol.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8427/Dec2009
-
ASTM International Committee F32 on Search and Rescue is currently developing a number of proposed new standards. Two of the proposed standards under the jurisdiction of Subcommittee F32.02 on Management and Operations are WK23984 , Guide for Level 1 (Basic) Mounted Search and Rescue (MSAR) Responder, and WK24699, Guide for Training for Land SAR as a Level 1 Out of Area Disaster Responder.…
-
Those involved in the rehabilitation of pressurized piping systems are invited to participate in the development of a proposed new standard, ASTM WK24231 , Practice/Guide for Internal Pipe Epoxy Barrier Coating Material Used in Pressurized Piping Systems. The proposed standard is being developed by Subcommittee F17.67 on Trenchless Plastic Pipeline Technology, part of ASTM International Committee…