Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed ASTM standard could help improve workplace safety by describing proximity alarm systems that can be used to prevent cranes, utility trucks, and other equipment from encroaching inside OSHA minimum approach distances and contacting high-voltage power lines. The standard would be most useful to the construction industry, but it could also help in firefighting, drilling, mining,…, ASTM Committee F18 on Electrical Protective Equipment for Workers Next Meeting:, Oct. 4-7, 2015, Las Vegas, Nev., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Lance Burney, Sigalarm, Sanford, Fla., tel +1.407.321.0722; lance@sigalarminc.com , ASTM Staff Contact:, Kevin Shanahan, tel +1.610.832.9737; kshanahan@astm.org Release #9903
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…
-
A new ASTM International standard, F 2621 , Practice for Determining Response Characteristics and Design Integrity of Arc Related Finished Products in an Electric Arc Exposure, is the latest in a series of standards developed by Subcommittee F18.65 on Wearing Apparel to reduce the number of fatalities and injuries caused by electric arcs. ASTM Practice F 2621 provides procedural guidelines for…
-
Joe Koury, staff manager for ASTM International Committee E52 on Forensic Psychophysiology, will speak at the annual seminar of the American Association of Police Polygraphists on April 17 at the Hotel Albuquerque at Old Town in Albuquerque, N.M. This meeting will follow the April 14-15 meetings of Committee E52, which will take place at the some hotel. In his presentation, Koury will provide an…
-
Forensic Psychophysiology Committee in ASTM International Aims at Reducing Perjury with New StandardThe aim of a new ASTM standard developed by Committee E52 on Forensic Psychophysiology is to assist the judicial system in reducing incidents of perjury. The new standard, E 2324, Guide for PDD Paired Testing, is under the jurisdiction of Subcommittee E52.05 on Psychophysiological Detection of Deception (PDD). According to George Baranowski, founder, Mindsight Consultants, the guide could be…