Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International guide responds to a decades-long need to enhance safety surrounding protective coating systems at nuclear power plants. The new standard (soon to be published as D8104, Guide for Determining Coating Qualification Test Data Applicability) was developed by ASTM International’s committee on protective coating and lining work for power generation facilities ( D33 ). According…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Jon R. Cavallo, PE, tel +1.603.767.8650; jrcpe@aol.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org R elease #10288
-
A proposed new ASTM International standard will help determine how well a kitchen range hood exhausts pollutants from a stovetop. These pollutants include moisture, odors, and chemicals and particles that are health hazards. The proposed standard (WK55797, Test Method for Measuring Capture Efficiency of Domestic Range Hoods) is being developed by ASTM International’s committee on performance of…, ASTM Committee E06 on Performance of Buildings Next Meeting:, April 2-5, 2017, April Committee Week, Toronto, Ontario, Canada, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Iain Walker, Lawrence Berkeley National Laboratory, Berkeley, Calif., tel +1.510.486.4692; iswalker@lbl.gov, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10252
-
ASTM International’s committee on performance of buildings ( E06 ) is creating a standard that will help determine qualifications of people who want to serve as inspectors of certain fire resistive materials. The committee welcomes input from people with knowledge of spray-applied fire resistive materials (SFRM) and intumescent fire resistive materials (IFRM). “Having a standard that outlines…, ASTM Committee E06 on Performance of Buildings Next Meeting:, April 2-5, 2017, April Committee Week, Toronto, Canada, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, John D. Nicholas, Perceptive Solutions LLC, Selma, Texas, tel +1.210.601.1119; john@perceptivesolutionsllc.com, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10220
-
A proposed ASTM International standard will provide a visual assessment and sampling protocol to determine if a dust-lead hazard remains following clean-up of an activity that has or may have disturbed lead-based paint. The proposed standard ( WK52690 , Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings, in Individual Units of Multi-Family…, ASTM Committee E06 on Performance of Buildings Next Meeting:, Oct. 23-26, 2016, October Committee Week, Orlando, Florida., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Kenn White, Consultive Services, tel +1.757.499.4420; kennwhite@cox.net, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10148
-
A proposed ASTM standard will provide a needed set of guidelines for conducting and reporting on the on-site inspections of fire resistive materials. Anyone interested, particularly people with inspection experience, is invited to help create the standard ( WK54567 , Practice for the On-Site Inspection of Installed Fire Resistive Materials). Both spray-applied (SFRM) and intumescent (IFRM)…, ASTM Committee E06 on Performance of Buildings Next Meeting:, Oct. 23-26, 2016, October Committee Week, Orlando, Fla., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Phil Mancuso, Isolatek International, Stanhope, N.J., tel +1.800.631.9600 ext. 214; pmancuso@isolatek.com, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10114
-
ASTM is launching a new subcommittee that will develop test methods and specifications for coatings and linings used in hydroelectric power plants. The new group is part of the Committee on Protective Coatings and Lining Work for Power Generation Facilities ( D33 ). Subcommittee D33.13 on Protective Coatings and Linings for Hydroelectric Power Generation Facilities will address abrasion,…, ASTM Committee D33 on Protective Coatings and Lining Work for Power Generation Facilities Next Meeting:, July 20–21, 2016, West Conshohocken, Pa., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Allen Skaja, U.S. Bureau of Reclamation, Lakewood, Colo., tel +1.303.445.2396; askaja@usbr.gov, ASTM Staff Contact:, Joe Hugo, tel +1.610.832.9740; jhugo@astm.org Release #10113
-
ASTM International has developed a standard that will allow engineers to effectively use hygrothermal models, a type of mathematical model that helps manage heat and moisture flow in buildings. The new standard (soon to be published as E3054, Guide for Documentation of Hygrothermal Models for Moisture Control Design in Building Envelopes) is the first of several that will provide guidance for…, ASTM Committee E06 on Performance of Buildings Next Meeting:, Oct. 23-26, 2016, October Committee Week, Orlando, Fla., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Mikael Salonvaara, Owens Corning Sustainability, Jefferson, Ga., tel +1.706.654.0892; Mikael.salonvaara@owenscorning.com , ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10045
-
ASTM International has published a new standard to help identify and classify building systems, components, sub-components and their attributes. The new standard ( E3035 , Classification for Facility Asset Component Tracking System (FACTS)) will optimize how assets and their associated functions and attributes are identified, tracked and used in modern buildings. “The new standard drills deep…, ASTM Committee E06 on Performance of Buildings Next Meeting:, April 10-13, 2016, April Committee Week, San Antonio, Texas, Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, William H. Hunt, GSA Central Office, Atlanta, Ga., tel +1.404.526.3168; william.hunt@gsa.gov , ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #9976
-
A newly published ASTM International guide provides standard notation, syntax and symbols for facade inspections while a second guide has been proposed to standardize how drones are used for facade inspections. The first standard ( E3036 , Guide for Notating Façade Conditions in the Field) will save time by providing engineers, architects and others with a common way to use and understand symbols…, ASTM Committee E06 on Performance of Buildings Next Meeting:, April 10-13, 2016, April Committee Week, San Antonio, Texas, Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Michael Petermann, Wiss, Janney, Elstner Associates Inc., New York, New York, tel +1.212.760.2540; mpetermann@wje.com, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #9978
-
A proposed new ASTM International standard will help minimize confusion in quantifying the texture value (smoothness/roughness) at the surface of concrete. The standard (WK49335, Test Method for Concrete Micro Surface Texture) will be used to measure concrete surfaces with a contact stylus instrument (profilometer). It will describe how to use the profilometer and reliable data indexes, allowing…, ASTM Committee E06 on Performance of Buildings Next Meeting:, April 10-13, 2016, April Committee Week, San Antonio, Texas, Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Andrew Bowman, Adaptive Concrete Innovations LLC, tel +1.419.408.5906; bb@aciconcrete.net , ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #9943