Search
Advanced search
Filter by category
Filter by committee
Search results
-
Keeping used materials out of landfills is a central goal of any industry that is attempting to become more sustainable. Finding creative ways to repurpose these materials is an added challenge, but one that ASTM International Committee D08 on Roofing and Waterproofing has begun to tackle with a proposed new standard, ASTM WK46625 , Guide for Establishing a Recycle Program for Roof Covers. “With…, ASTM Committee D08 Next Meeting:, Dec. 7-10, December Committee Week, New Orleans, La., Technical Contact:, Joseph J. Schwetz, tel +1.781.332.3224; schwetz.joe@us.sika.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9709
-
Using a new ASTM International standard will make it easier to simultaneously identify multiple outliers in a data set. The new standard is ASTM D7915 , Practice for Application of Generalized Extreme Studentized Deviate (GESD) Technique to Simultaneously Identify Multiple Outliers in a Data Set. “The impetus for developing D7915 was to provide a method for identifying outliers that is robust…, ASTM Committee D02 Next Meeting:, Dec. 7-11, San Diego, Calif., Technical Contact:, Alex T. Lau, TCL Consulting, Whitby, Ontario, Canada, tel +1.905.665.7995; alextclau@rogers.com, ASTM Staff Contact:, Alyson Fick, tel +1.610.832.9710; afick@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9700
-
The presence of ethylene glycol in in-service motor oil indicates that antifreeze coolant has leaked into the crankcase of an internal combustion engine. Such leakage leads to engine wear problems. A new ASTM International standard will be used to effectively determine whether glycols are present in motor oil. The new standard is D7922 , Test Method for Determination of Glycol for In-Service…, ASTM Committee D02 Next Meeting:, Dec. 7-11, 2014, San Diego, Calif., Technical Contact:, Frank P. DiSanzo, Ph.D., ExxonMobil Research and Engineering, Annandale, N.J., Phone: +1.908.730.2815; frank.p.disanzo@exxonmobil.com, ASTM Staff Contact:, Alyson Fick, Phone: +1.610.832.9710; afick@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: +1.610.832.9603; bschindl@astm.org Release #9702
-
If you have a roof over your head, chances are very good that you have flashing over your head as well. Flashing serves as part of the weather resistant barrier systems that keep water from getting into a structure. A proposed new ASTM International guide will satisfy a market need for a standard to define durable flashing and will create a level playing field for flashing manufacturers. The…, ASTM Committee D08 Next Meeting:, Dec. 7-10, December Committee Week, New Orleans, La., Technical Contact:, Michael Schmeida, Oatey Co., Cleveland, Ohio, tel +1.216.898.3469; mschmeida@oatey.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9694
-
Excess moisture trapped in roofing or waterproofing systems can adversely affect performance, as well as lead to premature failure of a system and its components. Using an electrical impedance scanner is a fast and relatively easy way to conduct moisture surveys of roofing and waterproofing systems. A new ASTM International standard covers the use of electrical impedance scanners to monitor the…, ASTM Committee D08 Next Meeting:, Dec. 7-10, 2014, December Committee Week, New Orleans, La., Technical Contact:, Sean Fallon, Sean Fallon Consulting, Dublin, Ireland, Phone: +353-1-2851861; seanfallon14@gmail.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9674
-
A proposed new ASTM standard will be used to ensure that the waterproofing of buildings is performing as intended. Once approved, the practice will be useful to architects, specifiers, membrane manufacturers, roofing contractors and warranty providers, as well as building owners, to test, verify and monitor the integrity of waterproof membranes. ASTM WK27666, Practice for Electrical Conductance…, ASTM Committee D08 Next Meeting:, June 22-25, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, David Vokey, Detec Systems, Bellingham, Wash.; Phone: 360-961-9452; david.vokey@detecsystems.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9593
-
Renewable Synthesized Iso-Paraffinic (SIP) fuel has now been included in ASTM International standard D7566 , Specification for Aviation Turbine Fuel Containing Synthesized Hydrocarbons. A recently approved revision that adds SIP fuel to the ASTM D7566 annex will facilitate use of the fuels in all airlines internationally. “The introduction of renewable fuel into the aviation industry enables a…, ASTM Committee D02 Upcoming Meetings:, June 22-26, 2014, D02 June meeting, Indianapolis, Ind.; and Dec. 7-14, 2014, D02 December meeting, San Diego, Calif., Technical Contact, : Olivier Rolland, Total New Energies USA, Emeryville, Calif., Phone: 510-788-6732; olivier.rolland@total.com ; Fernando J. Garcia, Amyris, Emeryville, Calif., Phone: 510-597-4835; garcia@amyris.com, ASTM Staff Contact:, Alyson Fick, Phone: 610-832-9710; afick@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9590
-
ASTM International Committee D08 on Roofing and Waterproofing , through its Subcommittee D08.24 on Sustainability , is developing several standards for sustainable roofing systems. One such standard is ASTM WK26599 , Guide for Design of Sustainable, Low-Slope Roofing Systems. “The proposed standard embraces the fact that the primary purpose of the roofing system is to protect the top of the…, ASTM Committee D08 Next Meeting:, Dec. 8-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Eric K. Olson, P.E., Simpson Gumpertz & Heger, Waltham, Mass., Phone: 781-907-9311; ekolson@sgh.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9478
-
Butanol shows strong potential to be used as a biofuel. Now, a new ASTM International standard covers butanol that is intended to be blended with gasoline at 1 to 12.5 volume percent for use as an automotive spark-ignition engine fuel. ASTM D7862-13 , Specification for Butanol for Blending with Gasoline for Use as Automotive Spark-Ignition Engine Fuel, was developed by Subcommittee D02.A0 on…, ASTM Committee D02 Next Meeting:, Dec. 8-12, 2013, Tampa, Fla., Technical Contact:, Glenn Johnston, Gevo Inc., Englewood, Colo., Phone: 720-267-8600; gjohnson@gevo.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9473
-
A proposed ASTM standard will reflect recent technological advances for asphalt adhesives. ASTM WK40056 , Specification for Adhesive Used with Modified Bituminous Sheet Materials, is being developed by Subcommittee D08.20 on Roofing Membrane Systems , part of ASTM International Committee D08 on Roofing and Waterproofing . “The proposed standard will provide a means of describing the changes that…, ASTM Committee D08 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Carter C. Slusher, Firestone Building Products, Indianapolis, Ind., Phone: 317-575-7117; slushercarter@gbsg.net, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9322